線上Solaris機器有一台有內存錯誤,但是prtdiag -v時候看不到fault信息。
======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 64 GB 8 8 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
8 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
8 GB MB/CMP1/BR0/CH0/D0
MB/CMP1/BR0/CH1/D0
8 GB MB/CMP1/BR1/CH0/D0
MB/CMP1/BR1/CH1/D0
8 GB MB/CMP0/BR0/CH0/D1
MB/CMP0/BR0/CH1/D1
8 GB MB/CMP0/BR1/CH0/D1
MB/CMP0/BR1/CH1/D1
8 GB MB/CMP1/BR0/CH0/D1
MB/CMP1/BR0/CH1/D1
8 GB MB/CMP1/BR1/CH0/D1
MB/CMP1/BR1/CH1/D1
進入console口,用console的系統命令查看
show /SP/faultmgmt,看到2個槽上內存有問題。
-> show faultmgmt
/SP/faultmgmt
Targets:
shell
0 (/SYS/MB/CMP0/BR1/CH1/D1)
1 (/SYS/MB/CMP0/BR1/CH1/D0)
Properties:
Commands:
cd
show
更換完內存應該是如下狀態,沒有報錯。
-> show /SP/faultmgmt
/SP/faultmgmt
Targets:
shell
Properties:
Commands:
cd
show